STAC6-C Quick Setup Guide
Requirements
A small at blade screwdriver for tightening the connectors (included). ▪
A personal computer running Microsoft Windows 98, 2000, ME, NT, XP, Vista or 7. ▪
STAC Congurator™ ▪ software (available at www.applied-motion.com).
An RS-232 Applied Motion programming cable (included) ▪
4 pin spring connector (included) for connecting to the CAN network. ▪
A compatible stepper motor ▪
For more detailed information, please download and read the ▪ STAC6 Hardware Man-
ual, available at www.applied-motion.com/support/manuals.
To begin, make sure you have the following equipment:
Step 1 - Wiring
920-0042 A
920-0046 A
STAC6-C Quick Setup Guide
Wire the drive to the AC power source. ▪
(Do not apply power until Step 3)
Note: The STAC6-C uses 120VAC single-phase power.
The STAC6-C-220 uses 220VAC single-phase power.
If using an external fuse, we recommend the follow-
ing:
STAC6-C: 6 amp fast acting
STAC6-C-220: 3 amp fast acting
See the hardware manual for more information
about connecting AC power.
Ensure a proper earth ground connection.
Node ID CANOpen Connector Bit Rate Motor Connector
Power Connection Encoder Connector I/O Connector RS232 Connector
Connect the drive to the motor. ▪
Refer to the wiring diagrams below. For details and rec-
ommended motors, see the STAC6 Hardware Manual.
Connect the I/O ▪
Connect the Encoder ▪
white
green
red
black
shield
brown
orange
yellow
blue
A+ A- B+ B- FG
X COMMON
X3 / Enable
X5 / CW JOG
X4 / Alarm Reset
Analog IN
Analog IN
X2 / DIR -
X2 / DIR +
X1 / STEP+
X1 / STEP -
GND
GND
X8/CCW LIMIT -
X8/CCW LIMIT+
X7/CW LIMIT -
X7/CW LIMIT+
Y4 -
Y4+
+5V OUT
Y COMMON
Y3 / FAULT
Y2 / MOTION
Y1 / BRAKE
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
2
3
1
19
20
21
22
23
24
25
X6 / CCW JOG
IN/OUT - ST5/10 - Q/Si
Z+ (5)
NC (10)
B- (4)
NC (9)
B+ (3)
NC (13)
NC (14)
NC (15)
(12) NC
(11) NC
(6) Z-
(1) A+
(7) +5VDC 200mA
(2) A-
(8) GND
PC GND
PC TX-/RX- or B
PC TX+/RX+ or A
+RX- +TX- GND
Drive 1 Drive 2 Drive 3
+RX- +TX- GND +RX- +TX- GND
PC GND
PC RX-
PC RX+
PC TX-
PC TX+
+RX- +TX- GND
Drive 1 Drive 2 Drive 3
+RX- +TX- GND +RX- +TX- GND
Front View
X COMMON
X7 / CW Limit
X3 / Enable
X5
X4 / Alarm Reset
Analog IN-
Analog IN+
X2 / DIR-
X2 / DIR+
X1 / STEP +
X1 / STEP -
GND
GND
+5V OUT
Y COMMON
Y3 / FAULT
Y2 / MOTION
Y1 / BRAKE
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
2
3
1
19
20
21
22
23
24
25
X6 / CCW Limit
IN/OUT 1
+5V OUT
+12V OUT
GND
GND
ENCODER *Optional
A+
A–
B+ B–
8
lead
motor
Series Connected 8 Leads Parallel Connected
A+
A–
B+
B–
8
lead
motor
White
Orange
Brown
Green
Red
Yellow
Blue
Black
Orange
Red
Brown
Yellow
Blue
Black
White
Green
Motor Connector
Comments to this Manuals