Applied-motion 1035D User Manual

Browse online or download User Manual for Hardware Applied-motion 1035D. Applied Motion 1035D User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
User's Manual
2 Axis
Step Motor Driver
motors • drives • controls
Applied Motion Products, Inc.
404 Westridge Drive Watsonville, CA 95076
Copyright 2003
Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544
1035D
10/15/03
1035man.ai
3362
3362
0-1A
0-1A
A+
A–
B+
B–
A+
A–
B+
B–
STEP
DIR
COM
DIR
STEP
1035D
axis 1 axis 2
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - User's Manual

User's Manual2 AxisStep Motor Drivermotors • drives • controlsApplied Motion Products, Inc.404 Westridge Drive Watsonville, CA 95076Copyright 20

Page 3 - Introduction

FeaturesTechnical Specifications-3--14-Drives two step motors independently.Pulse width modulation switching amplifiers.Phase current from 0 to 1.0 am

Page 4 - Getting Started

336233620-1A0-1AA+A–B+B–A+A–B+B–STEPDIRCOMDIRSTEP1035Daxis 2 current adjustmentstep & directioninputsaxis 2 motorconnectoraxis 1 motorconnectoraxi

Page 5 - Connecting the Power Supply

motorsupply12-35 VDC+–Connecting the MotorWarning: When connecting the motor to the driver, be sure that themotor power supply is off. Secure any un

Page 6 - Choosing a Power Supply

A+A-B+ B-8leadmotor8 Leads Series ConnectedEight lead motors can also be connected in two ways: series and parallel. Aswith six lead motors, series

Page 7 - Connecting A Pulse Source

-7--10-Motor Size Winding Max Torque CurrentNumber inches Connection oz-in Amps5014-842 1.38 x 1.38 x 1.57 4 lead 22 1.05017-006 1.65 x 1.65 x 1.34 ce

Page 8 - NAiS FP0 PLC

Selecting Between Full and Half Step Operation-8- -9-Idle Current ReductionThe 1035D includes a feature that automatically reduces the motor current b

Comments to this Manuals

No comments